Digital
I/O
-
4 inputs, 24 V industrial logic, isolated
-
4 outputs, 24 V industrial logic, isolated,
0,5 A
Analog I/O
-
2 inputs ± 10 V 10 Bit, 2 outputs
± 10 V 8 Bit
-
2 inputs ± 10 V 16 Bit, 2 outputs
± 10 V 16 Bit
-
2 inputs ± 10 V 12 Bit, 2 outputs
± 10 V 12 Bit
SinCos encoder
With hiperface interface and electronic
rating plate. Resolution up to several million
incr./rev.
Resolver
Resolution: 1024 incr./rev.
5V-square-wave incremental encoder
Resolution: (stroke no. x 4) incr./rev.
Incremental encoder emulation
5V-square-wave/differential signal, 90°
phase shift
Field bus modules
b maXX 4400 supports all conventional field
bus
systems. b maXX can be optimally integrated
into
all systems by simply replacing the corresponding
option module. EtherCAT is the standard
field bus
Storage module
The parameter storage module contains all
the parameters that are set on the drive
controller of the b maXX for all parameter
data records and all positioning profiles.
The drive controller can be provided with
new parameters by simply plugging in the
module. Given that the parameter
module is pluggable, a drive can be replaced
during servicing without the need for any
know-ledge of the operating software.
Servicing could not be easier.
|